Motive/Traction Batteries 158MM

Technical Specifications

BS Width (158MM) Tubular Traction Cells
Overall Height - H1 (mm) max 235 285 350 425 480 540 595 630 715
Cell Height - H (mm) max 210 260 325 400 455 515 570 605 690
Width in MM Length in MM No. of position Plates
BT 21 BT 30 BT 42 BT 55 BT 65 BT 75 BT 86 BT 100 BT 110
158 61 3 ah/c5
   kg.   
63
   4.9   
90
   6.6   
126
   8.5   
165
   10.4   
195
   11.8   
225
   13.5   
258
   14.8   
300
   16.5   
330
   19.0   
158 77 4 ah/c5
   kg.   
84
   6.4   
120
   8.2   
168
   10.9   
220
   13.4   
260
   15.3   
300
   17.5   
344
   19.2   
400
   21.2   
440
   24.4   
158 93 5 ah/c5
   kg.   
105
   7.7   
150
   10.3   
210
   13.2   
275
   16.4   
325
   18.7   
375
   21.4   
430
   23.4   
500
   26.0   
530
   30.0   
158 109 6 ah/c5
   kg.   
126
   9.1   
180
   12.1   
252
   15.7   
330
   19.4   
390
   22.0   
450
   25.3   
516
   27.7   
600
   30.7   
660
   35.5   
158 125 7* ah/c5
   kg.   
147
   10.5   
210
   13.9   
294
   18   
385
   22.3   
455
   25.5   
525
   29.2   
602
   31.9   
700
   35.6   
770
   40.9   
158 141 8* ah/c5
   kg.   
168
   11.9   
240
   15.9   
336
   20.4   
440
   25.4   
520
   28.9   
600
   33.1   
688
   36.3   
800
   40.6   
880
   46.8   
158 157 9* ah/c5
   kg.   
189
   13.3   
270
   17.8   
378
   22.8   
495
   28.4   
585
   32.3   
675
   37.1   
774
   40.8   
900
   45.5   
990
   52.3   
158 173 10* ah/c5
   kg.   
210
   14.9   
300
   19.8   
420
   25.7   
550
   31.6   
650
   36.0   
750
   41.2   
860
   45.1   
1000
   50.2   
1100
   57.8   
158 189 11* ah/c5
   kg.   
231
   16.3   
330
   21.7   
462
   28.1   
605
   34.5   
715
   39.4   
825
   45.1   
946
   49.4   
1100
   54.9   
1210
   63.2   
158 205 12* ah/c5
   kg.   
252
   17.7   
360
   24.0   
504
   30.4   
660
   37.6   
780
   42.7   
900
   49.0   
1032
   53.6   
1200
   59.7   
1320
   68.7   

All dimensions are subject to usual production tolerances. Weights mentioned are filled weights, subject to tolerance of + 5%

Charging Recommendations

Single Rate Taper Charger

For Tropical Climate

Starting Current : 12.5 % of C5 Amps

Finishing Current : 6 % of C5 Amps Approx.

Charging Time : 10 Hours.

For Temperate Climate

Starting Current : 22 % of C5 Amps

Finishing Current : 6 %ofC5Amps Approx.

Charging Time : 7 Hours.